Table 1. IPNV physical particles (PP) counted on membrane filters using immunofluorescence (mAb) and SYBR-Green I. |
Descriptive Statistics |
Immunofluorescence (mAb) |
SYBR-Green I |
Average PP per field (n = 10) |
4,481 |
3,624 |
Total PP per filter |
3.6 x 107 |
2.9 x 107 |
Standard error of total PP |
0.47 x 107 |
0.23 x 107 |
Confidence interval (α = 0.05) |
3.1 x 107; 4.0 x 107 |
2.7 x 107; 3.1 x 107 |
Sample error |
0.21 x 107 |
0.10 x 107 |
|
|